This is NKS NKS-R NKS-B News Seminars NKS Reports Phantom Library

You are here: Homepage Documents test View document

 

View document

NKS Programme Area:NKS-R
Research Area:Thermo hydraulics
Report Number:NKS-225
Report Title:Modeling of Condensation, Stratification, and Mixing Phenomena in a Pool of Water
Activity Acronym:POOL
Authors:H. Li, P. Kudinov, W. Villanueva
Abstract:This work pertains to the research program on Containment Thermal-Hydraulics at KTH. The objective is to evaluate and improve performance of methods, which are used to analyze thermal-hydraulics of steam suppression pools in a BWR plant under different abnormal transient and accident conditions. As a passive safety system, the function of steam pressure suppression pools is paramount to the containment performance. In the present work, the focus is on apparently-benign but intricate and potentially risk-significant scenarios in which thermal stratification could significantly impede the pool’s pressure suppression capacity. For the case of small flow rates of steam influx, the steam condenses rapidly in the pool and the hot condensate rises in a narrow plume above the steam injection plane and spreads into a thin layer at the pool’s free surface. When the steam flow rate increases significantly, momentum introduced by the steam injection and/or periodic expansion and shrink of large steam bubbles due to direct contact condensation can cause breakdown of the stratified layers and lead to mixing of the pool water. Accurate prediction of the pool thermal-hydraulics in such scenarios presents a computational challenge. Lumped-parameter models have no capability to predict temperature distribution of water pool during thermal stratification development. While high-order-accurate CFD (RANS, LES) methods are not practical due to excessive computing power needed to calculate 3D high-Rayleigh-number natural circulation flow in long transients. In the present work, a middle-ground approach is used, namely CFD-like model of the general purpose thermal-hydraulic code GOTHIC. Each cell of 3D GOTHIC grid uses lumped parameter volume type closures for modeling of various heat and mass transfer processes at subgrid scale. We use GOTHIC to simulate POOLEX/PPOOLEX experiment, in order to (a) quantify errors due to GOTHIC’s physical models and numerical schemes, and (b) propose necessary improvements in GOTHIC sub-grid scale modeling. The study performed on thermal stratification in a water pool indicates that GOTHIC CFD-like model is fit for reactor applications in complex fluid-physics scenarios that avoids both over-simplification (as in single lumped-parameter model) and over-complication (as in CFD models). However, simulation of direct steam injection into a subcooled pool cannot be predicted reliably with the existing models. Thus we develop “effective heat source” and “effective momentum” approaches, and provide feasibility study for the prediction of thermal stratification and mixing in a BWR pressure suppression pool. The results are encouraging and further activity on the development and implementation of the proposed models in GOTHIC is currently underway.
Keywords:BWR pressure suppression pool; thermal stratification; mixing; effective models; GOTHIC
Publication date:01 Dec 2010
ISBN:ISBN 978-87-7893-295-2
Number of downloads:2188
Download:pdf NKS-225.pdf
Contact NKS   NKS Sekretariatet
Boks 49
DK-4000 Roskilde
  Telephone +45 46 77 40 41
E-mail: nks@nks.org 
 

Address for visitors
Directions and map

Privacy policy

Cookie policy

 

Website last modified: 19 November 2024